Plan installation from the approved drawing
The source article outlines a sequence from locating the door to final checks. Actual installation must follow the approved project drawings and the instructions for the selected door and cell.

- Confirm the opening: verify the dimensions, mounting position and opening direction against the site layout.
- Prepare the supports: confirm that the supporting structure and attachment points match the approved design.
- Align the guides: install and check the guides for the alignment required by the door design.
- Fit the curtain: install the curtain or door elements and check their connections and travel path.
- Install the drive and controls: complete the electrical and control connections according to the supplied diagrams and local requirements.
- Commission movement: check opening, closing, stopping and the configured signals with the door and cell teams.
- Complete handover checks: document the final settings, operating instructions and any items that remain to be confirmed.
Installation and commissioning should be completed by qualified personnel. Any safety functions, PLC interlocks and site-specific acceptance checks must be verified as part of the complete cell system.